Medical imaging

One-class anomaly detection fits medicine well. Normal studies are plentiful while pathologies are rare, varied and expensive to annotate, so a model that learns only from normal anatomy can flag what deviates from it: for screening triage, quality control or out-of-distribution checks before another model runs.

Medical images are different from photographs, though, and this page explains how to adapt imgad to them.

Research use only

imgad is a research tool, not a medical device. Several of the models below are released for research use only (see their licenses). Any clinical use needs validation on your own data and the applicable regulatory approval.

1. Read the images correctly

pip install "imgad[medical]"      # pydicom + nibabel + timm + open_clip (medical model zoo)

Medical images usually have more than 8 bits: 12–16-bit X-ray detectors, CT in Hounsfield units, MRI intensities. Foundation models expect 8-bit RGB, so imgad maps every image with an intensity rule. 8-bit images are never changed.

Rule When to use it
window:lo,hi Default choice for anomaly detection. The same mapping for every image, so a globally brighter or darker study stays different. CT: a radiological window in HU; X-ray: the detector range, e.g. window:0,4095
dicom Use the window stored in each DICOM file (as radiologists view it). Different files may use different windows
percentile:1,99 / minmax Per-image normalisation. Robust to scanner differences, but hides global intensity anomalies
auto 8-bit unchanged; DICOM window if present; else percentiles 0.5–99.5

Typical CT windows (center/width → window:lo,hi):

Window Center / width (HU) Rule
Brain 40 / 80 window:0,80
Soft tissue / abdomen 40 / 400 window:-160,240
Lung −600 / 1500 window:-1350,150
Bone 400 / 1800 window:-500,1300
from imgad import HFFeatureExtractor, benchmark, build_extractor

ext = HFFeatureExtractor("microsoft/rad-dino").set_intensity("window:0,4095")
ext = build_extractor({"type": "hf", "model_name": "microsoft/rad-dino", "intensity": "dicom"})
rows = benchmark(..., intensity="window:-160,240")   # every model that does not set its own rule

From the CLI: imgad fit ... --intensity window:0,4095 or intensity: at the top of the benchmark YAML. The rule is part of the feature-cache key and is stored with the trained model, so inference uses the same mapping.

DICOM (.dcm) files can be used anywhere a path is accepted, including folders and MVTec-style layouts. imgad applies the rescale slope/intercept (CT → HU) and inverts MONOCHROME1 so that bright means dense. It reads only the pixel data: patient name, IDs and dates are never stored, logged or written to results.

Volumes (CT, MRI)

NIfTI volumes and multi-frame DICOM are analysed slice by slice. data.volume_slices returns references such as "scan.nii.gz::z=42", which every imgad function accepts as image paths:

from imgad import AnomalyDetectionPipeline, data

train = data.volume_slices("normal_scans/", axis="z", step=2)       # skips empty slices
test = data.volume_slices("new_scans/", axis="z")
pipe = AnomalyDetectionPipeline({"type": "hf", "model_name": "facebook/dinov2-base",
                                 "intensity": "window:0,80"}, "mahalanobis", preprocessing=["l2"])
pipe.fit(train)
scores = pipe.score(test)

Volumes are reoriented to RAS, so the x/y/z axes are comparable across files. Each slice gets its own score, so aggregate the slice scores to decide per volume, e.g. with the maximum:

from collections import defaultdict
from imgad.imageio import file_of

per_volume = defaultdict(list)
for ref, s in zip(test, scores):
    per_volume[file_of(ref)].append(s)
volume_score = {v: max(s) for v, s in per_volume.items()}

2. Choose a feature extractor

General-purpose models (DINOv2/v3, CLIP, SigLIP) are strong baselines. Domain-specific models often do better, and imgad can benchmark both under the same protocol. The model zoo (imgad.zoo) has ready-to-use recipes for medical feature extractors, with their access and license, and recommends a set to benchmark for each modality:

imgad models --modality histopathology            # domain models first, then general baselines
imgad models -m cxr --public-only --check         # only public models, with your access status
imgad models -m pathology --commercial --yaml     # exclude non-commercial licenses; YAML block for a benchmark
from imgad import build_extractor, zoo

for card in zoo.recommend("chest-xray"):
    print(card.name, card.access, card.license)
ext = build_extractor("zoo:rad-dino")             # also `- zoo:rad-dino` in a benchmark YAML

Modalities: chest-xray, ct, mri, histopathology, dermatology, ophthalmology, oct. Aliases such as cxr, pathology or fundus are accepted. Recommendations are ordered from specific to general: domain models covering the fewest modalities first (models trained on that modality only, then broader medical models), then general baselines. They are a starting point to benchmark on your own data, not a quality ranking. Eye imaging (fundus and OCT) has its own page: Ophthalmology.

Name Modalities Access License / terms Dim Notes
zoo:rad-dino chest-xray public MIT 768 DINOv2-B continued on chest X-rays from five public datasets (MIMIC-CXR, CheXpert, NIH-CXR, PadChest…); no text supervision.
zoo:medsiglip chest-xray, ct, mri, dermatology, ophthalmology, histopathology gated Health AI Developer Foundations terms – SigLIP image encoder (448 px) trained on medical image–text pairs: chest X-ray, CT/MRI slices, dermatology, ophthalmology, histopathology.
zoo:biomedclip chest-xray, ct, mri, dermatology, ophthalmology, oct, histopathology public MIT 512 CLIP ViT-B/16 trained on PMC-15M (15M figure–caption pairs from PubMed Central): broad but figure-style images. Needs open_clip.
zoo:uni2-h histopathology gated CC-BY-NC-ND-4.0 1536 ViT-H/14 on >200M H&E and IHC tiles from >300k slides.
zoo:uni histopathology gated CC-BY-NC-ND-4.0 1024 ViT-L/16 on ~100M tiles from ~100k H&E slides (Mass-100K).
zoo:virchow2 histopathology gated CC-BY-NC-ND-4.0 2560 ViT-H/14 with 4 register tokens; embedding = class token + mean patch token, as in the model card.
zoo:h-optimus-0 histopathology gated Apache-2.0 1536 ViT-g/14; expects 224×224 tiles at 0.5 µm/px (its own normalisation is applied by timm).
zoo:prov-gigapath histopathology gated Apache-2.0 1536 Tile encoder (ViT-g) of Prov-GigaPath.
zoo:phikon-v2 histopathology public Owkin non-commercial license 1024 DINOv2 ViT-L/16 on ~456M tiles from 60k H&E slides (TCGA, CPTAC, GTEx…). Public, no request needed.
zoo:retfound-cfp ophthalmology gated CC-BY-NC-4.0 1024 RETFound (MAE ViT-L/16), colour-fundus weights of the Nature paper. Embedding = mean patch token after the encoder norm; ImageNet normalisation, 224 px.
zoo:retfound-oct oct gated CC-BY-NC-4.0 1024 RETFound (MAE ViT-L/16), OCT weights of the Nature paper (B-scans).
zoo:retfound-dinov2 ophthalmology gated CC-BY-NC-4.0 1024 RETFound retrained with DINOv2 (ViT-L/14, teacher weights) on part of the MEH AlzEye fundus cohort.
zoo:retfound-green ophthalmology public custom non-commercial licence 384 ViT-S/14 with 4 registers trained with token reconstruction on 75k public fundus images; 392 px, mean of patch tokens as in its README. Small (87 MB) and fast. Weights from the GitHub release.
zoo:flair ophthalmology public Apache-2.0 2048 Vision tower (ResNet-50) of the FLAIR vision–language model, trained with expert text descriptions on 38 public fundus datasets (288k images). Inputs in [0, 1] at 512 px; average-pooled features before the text projection.
zoo:urfound ophthalmology, oct public MIT 768 One ViT-B/16 encoder for both fundus and OCT, trained with knowledge-guided masked modelling on ~180k retinal images.
zoo:retizero ophthalmology public no license file in the repository 1024 Vision–language model (RETFound ViT-L/16 image encoder with LoRA, merged at load time) trained on 341,896 fundus images with text covering 400+ fundus diseases. Class token, 224 px. Weights (1.6 GB) from Google Drive.
zoo:visionfm-fundus ophthalmology public CC-BY-NC-4.0 768 VisionFM fundus encoder: iBOT ViT-B/16 (teacher weights), class token, with VisionFM's own fundus normalisation. Weights (1.5 GB) from Google Drive.
zoo:visionfm-oct oct public CC-BY-NC-4.0 768 VisionFM OCT encoder (iBOT ViT-B/16, teacher weights) with VisionFM's OCT normalisation. VisionFM also releases FFA, slit-lamp, external-eye, ultrasound, UBM and MRI encoders (same recipe).
zoo:retfound-cfp-mirror ophthalmology public CC-BY-NC-4.0 1024 Unofficial public copy of RETFound CFP weights in timm format (bitfount). Not verified against the official gated weights; prefer zoo:retfound-cfp when you have access.
zoo:retfound-oct-mirror oct public CC-BY-NC-4.0 1024 Unofficial public copy of RETFound OCT weights in timm format (bitfount); not verified against the official weights.
zoo:dinov2-base general baseline public Apache-2.0 768 Strong general self-supervised baseline.
zoo:dinov3-vitb16 general baseline gated DINOv3 license 768 Newer self-supervised baseline (gated).
zoo:siglip2-base general baseline public Apache-2.0 768 Vision–language baseline.

The facts above come from each model card (checked when the zoo was written). Verify them on the model page before relying on them, especially licenses and terms for any non-research use. imgad hf-check also shows the license declared in the model card.

  • Gated models (RETFound, UNI, Virchow2, H-optimus-0, Prov-GigaPath, MedSigLIP, DINOv3) need you to request access on their page and log in (imgad hf-login, see Gated models). Some, such as UNI and Virchow2, require an institutional e-mail.
  • Pathology models load through timm ({"type": "timm", ...}, installed with imgad[medical]), with the exact arguments from their model cards. Virchow2 uses the class token concatenated with the mean patch token, as its authors recommend.
  • Raw checkpoints (RETFound, VisionFM, RetiZero, FLAIR…) are loaded into a timm architecture with checkpoint / checkpoint_key / checkpoint_prefix and their own preprocessing (data_config); see Ophthalmology. Checkpoints are read without executing code.
  • Not included: CONCH (needs its own package). Add any model as a timm/hf spec or register your own extractor.

Lesions are local

A single global embedding per image dilutes small findings, as it does with small industrial defects. Intermediate layers (layer=[6, 9, 12], pooling="mean") and patch-level models (PatchCore through the Anomalib backend) localise better and give anomaly maps.

3. Use the medical benchmarks

Two public benchmarks with an anomaly-detection protocol:

  • BMAD (CVPR Workshops 2024). Six datasets: brain MRI (BraTS2021), liver CT (BTCV + LiTS), retinal OCT (RESC, OCT2017), chest X-ray (RSNA) and histopathology (Camelyon16). Each has train/good and valid/ / test/ folders with good and Ungood subfolders; brain MRI adds img/ and anomaly_mask/ subfolders. Code and data (CC BY-NC-SA).
  • MedIAnomaly (Medical Image Analysis, 2025). Seven datasets across chest X-ray, brain MRI, retinal fundus, dermatoscopy and histopathology, with 30 methods compared. Code and data.

The folder layouts plug into data.from_folders. Point at the image folders, not at the mask folders:

from imgad import data

brain = data.from_folders("BMAD/Brain/train/good/img", "BMAD/Brain/test/good/img",
                          ["BMAD/Brain/test/Ungood/img"], name="bmad/brain")
camelyon = data.from_folders("BMAD/Camelyon16/train/good", "BMAD/Camelyon16/test/good",
                             ["BMAD/Camelyon16/test/Ungood"], name="bmad/camelyon16")

Use the valid/ split to choose the detector, the intensity rule and the threshold, and keep test/ for the final numbers.

4. Evaluate like a clinical study

Most of what makes a medical evaluation credible is already in imgad, provided it is used carefully:

  • Split by patient, not by image. If one patient has several images or slices, put all of them on the same side of the split. Otherwise near-duplicates leak from training to test and inflate every metric. Build train_paths / test_paths from patient lists, and with volumes, split the volumes before calling volume_slices.
  • Report operating points, not only AUROC. Clinicians care about sensitivity at a fixed specificity (or the other way round). evaluate_scores gives FPR@95%TPR. calibrate_threshold(method="fpr", target_fpr=0.05) fixes the false-alarm rate on normal validation images, and method="tpr" fixes the sensitivity.
  • Quantify uncertainty. Medical test sets are small: use bootstrap=1000 for confidence intervals, several seeds with train_subsample for training variability, and DeLong to compare two models on the same images (Statistical analysis).
  • Check robustness across sites and scanners. Domain shift between hospitals is the main failure mode. Treat each site (or scanner, or subgroup) as a separate dataset in the benchmark: the per-dataset results and the Friedman/Wilcoxon tests show whether a model's ranking holds across sites.
  • Calibrate on the target site. The automatic threshold is estimated on the training distribution. Recalibrate it on a few normal studies from each new site (imgad calibrate --method fpr).

5. Protect patient data

  • Only pixel data is read from DICOM/NIfTI, but file paths end up in results, reports and logs. If your file names contain patient names or IDs, pseudonymise them before running imgad.
  • Benchmark reports include example images. Do not publish reports built on non-public data.
  • Hugging Face tokens are never stored by imgad (Gated models).

6. Not yet in imgad

These are natural next steps; contributions are welcome.

  • Patient-aware split helpers and a "sensitivity at fixed specificity" metric in reports.
  • Loaders for BMAD and MedIAnomaly.
  • Patch-level kNN on foundation-model features (anomaly maps without Anomalib).
  • Learned prompts and adapters for zero/few-shot detection, e.g. MVFA (CVPR 2024). Prompt-based zero/few-shot detection is available: guide.
  • Showing model licenses in benchmark reports.